Minimum Order Quantity | 1 Unit |
Usage/Application | OIL |
Model Name/Number | ATN-TRS400-F300-80NB |
Brand | ATN INSTRUMENTS |
Output | RS 485 |
Application Media | Any Liquid |
Display | Remote, LCD |
Operating Temperature | -20 to 120 Deg. C |
Flow Range | 40 - 600000 LPH |
Operating Pressure | 6 MPa |
Line Size | 15MM - 250 MM |
Power Supply | 230 VAC |
Accuracy | +- 1% FSD |
Country of Origin | Made in India |
Enclosure | SS 316 |
Rotor | SS 410 |
Shaft | Hard Stainless Steel-316 With Carbon Bush |
Accuracy Standard Installation Position | +/- 0.5 Or 1% Fsd |
Repeatability | 0.1% |
Maximum Working Pressure | 6 Mpa |
Fluid and Ambient Temperature | -20 To 120 Deg. C |
Connection | Flange |
Power Voltage | 12 V Dc |
Output Signal | Npn Open Connector |
High Electric Level | High Than 8vdc(Input Voltage 12 Vdc) |
Low Electric Level | Lower Than 0.8 Vdc( Input Voltage 12 Vdc) |
Display Sensor | ATN-F300 |
Function | Flow Transmitter |
Mounting | Field |
Size | Round Display |
Input | Pulse |
Supply | 230 Vac |
FIELD SS TURBINE FLOW TRANSMITTER - ATN-TRS400-F300-80NB
Turbine flow meter
ATN Instruments developed and design turbine flow meter available with varient of output : RS 484/ hart/ pulse/ current 4 -20 ma and voltage linear 0-10 vdc, conventional turbine flow sensor and meter for low viscous liquid and gas application, turbine flow sensor model number defined in two category,
1) Heavy duty turbine flow sensor and meter: it's a fully stainless steel meter with carbide bearing and available from 4mm to 400 mm line size
Minimum Order Quantity | 1 Piece |
Usage/Application | Automotive |
Model Name/Number | ATN-TRS400-P200-50NB |
Brand | ATN INSTRUMENTS |
Output | Nill |
Application Media | Any Liquid |
Display | Remote, Led |
Operating Temperature | -20 to 120 Deg. C |
Flow Range | 40 - 20000 LPH |
Operating Pressure | 6 MPa |
Line Size | 15MM - 50 MM |
Power Supply | 230 VAC |
Accuracy | +- 1% FSD |
Country of Origin | Made in India |
Shaft | Hard Stainless Steel-316 With Carbon Bush |
Accuracy Standard Installation Position | +/- 0.5 Or 1% Fsd |
Repeatability | 0.1% |
Maximum Working Pressure | 6 Mpa |
Fluid and Ambient Temperature | -20 To 120 Deg. C |
Connection | Thread (M/f) Or Flange |
Power Voltage | 12 V Dc |
Output Signal | Npn Open Connector |
High Electric Level | High Than 8vdc(Input Voltage 12 Vdc) |
Low Electric Level | Lower Than 0.8 Vdc( Input Voltage 12 Vdc) |
Display Sensor | ATN - P200 |
Function | Flow Totalizer |
Mounting | Pannel |
Size | 96x96 |
Input | Pulse |
Supply | 230 Vac |
PANEL SS TURBINE FLOW TOTALIZER - ATN-TRS400-P200-50NB
Turbine flow meter
ATN Instruments developed and design turbine flow meter available with varient of output RS 484/ hart/ pulse/ current 4 -20 ma and voltage linear 0-10 vdc, conventional turbine flow sensor and meter for low viscous liquid and gas application, turbine flow sensor model number defined in two category,
1) Heavy duty turbine flow sensor and meter it's a fully stainless steel meter with carbide bearing and available from 4mm to 400 mm line size
Usage/Application | Truck |
Model Name/Number | ATN-TRS400-F200-25NB |
Brand | ATN INSTRUMENTS |
Application Media | Any Liquid |
Display | Remote, LCD |
Operating Temperature | -20 to 120 Deg. C |
Flow Range | 40 - 600000 LPH |
Operating Pressure | 6 MPa |
Line Size | 15MM - 250 MM |
Power Supply | 230 VAC |
Size | Round Display |
Country of Origin | Made in India |
Accuracy Standard Installation Position | +/- 0.5 Or 1% Fsd |
Repeatability | 0.1% |
Maximum Working Pressure | 6 Mpa |
Fluid and Ambient Temperature | -20 To 120 Deg. C |
Connection | Flange |
Power Voltage | 12 V DC |
Output Signal | Npn Open Connector |
High Electric Level | High Than 8vdc(Input Voltage 12 Vdc) |
Low Electric Level | Lower Than 0.8 Vdc( Input Voltage 12 Vdc) |
Display Sensor | ATN-F200 |
Function | Flow Totalizer |
Mounting | Field |
Input | Pulse |
Output | Nill |
Supply | 230 Vac |
FIELD SS TURBINE FLOW TOTALIZER - ATN-TRS400-F200-25NB
Turbine flow meter
ATN Instruments developed and design turbine flow meter available with varient of output : RS 484/ hart/ pulse/ current 4 -20 ma and voltage linear 0-10 vdc, conventional turbine flow sensor and meter for low viscous liquid and gas application, turbine flow sensor model number defined in two category,
1) Heavy duty turbine flow sensor and meter: it's a fully stainless steel meter with carbide bearing and available from 4mm to 400 mm line size
Minimum Order Quantity | 1 Piece |
Usage/Application | Truck |
Model Name/Number | ATN-TRS400-F100-20NB |
Brand | ATN INSTRUMENTS |
Output | Nill |
Application Media | Any Liquid |
Display | Local, LCD |
Operating Temperature | -20 to 120 Deg. C |
Flow Range | 40 - 600000 LPH |
Operating Pressure | 6 MPa |
Line Size | 15MM - 250 MM |
Power Supply | 24 VDC |
Enclosure | S.S-316 |
Rotor | S.S-410 |
Shaft | Hard Stainless Steel-316 With Carbon Bush |
Accuracy Standard Installation Position | +/- 0.5 Or 1% Fsd |
Repeatability | 0.1% |
Maximum Working Pressure | 6 Mpa |
Fluid and Ambient Temperature | -20 To 120 Deg. C |
Connection | Thread (M/f) Or Flange |
Power Voltage | 12 V DC |
Output Signal | Npn Open Connector |
High Electric Level | High Than 8vdc(Input Voltage 12 Vdc) |
Low Electric Level | Lower Than 0.8 Vdc( Input Voltage 12 Vdc) |
Display Sensor | Atn - F100 |
Function | Flow Rate Indicator |
Mounting | Field |
Size | 96x96 |
Input | Pulse |
Supply | 230 Vac |
Field SS Turbine Flow Rate Indicator- ATN-TRS400-F100-20NB
ATN Instruments developed and design turbine flow meter available with varient of output RS 484/ hart/ pulse/ current 4 -20 ma and voltage linear 0-10 vdc, conventional turbine flow sensor and meter for low viscous liquid and gas application, turbine flow sensor model number defined in two category,
1) Economical turbine flow sensor and meter economical turbine flow sensor available with plastic/ aluminium rotor and body material aluminium / stainless steel, its available from 4mm to 50mm line size, more complete detail please contact company
Minimum Order Quantity | 1 Piece |
Usage/Application | Buses |
Model Name/Number | ATN-TRS400-P100-15NB |
Brand | ATN INSTRUMENTS |
Output | Nill |
Application Media | Any Liquid |
Display | Local, LED |
Flow Range | 40 - 20000 LPH |
Line Size | 15MM - 50 MM |
Power Supply | 230 VAC |
Accuracy | +- 1% FSD |
Country of Origin | Made in India |
Shaft | Hard Stainless Steel-316 With Carbon Bush |
Accuracy Standard Installation Position | +/- 0.5 Or 1% Fsd |
Repeatability | 0.1% |
Maximum Working Pressure | 6 Mpa |
Fluid and Ambient Temperature | -20 To 120 Deg. C |
Connection | Thread (M/f) |
Power Voltage | 12 V Dc |
Output Signal | Npn Open Connector |
High Electric Level | High Than 8vdc(Input Voltage 12 Vdc) |
Low Electric Level | Lower Than 0.8 Vdc( Input Voltage 12 Vdc) |
Display Sensor | ATN- P100 |
Function | Flow Rate Indicator |
Mounting | Pannel |
Size | 96x96 |
Input | Pulse |
Supply | 230 Vac |
PANNEL SS TURBINE FLOW RATE INDICATOR- ATN-TRS400-P100-15NB
Turbine flow meter
ATN Instruments developed and design turbine flow meter available with varient of output : RS 484/ hart/ pulse/ current 4 -20 ma and voltage linear 0-10 vdc, conventional turbine flow sensor and meter for low viscous liquid and gas application, turbine flow sensor model number defined in two category,
1) Heavy duty turbine flow sensor and meter: it's a fully stainless steel meter with carbide bearing and available from 4mm to 400 mm line size
Minimum Order Quantity | 1 Piece |
Usage/Application | Truck |
Model Name/Number | ATN-TRS400-P200R-40NB |
Brand | ATN INSTRUMENTS |
Application Media | OIL |
Display | Remote, LED |
Operating Temperature | -20 to 120 Deg. C |
Flow Range | 40 - 20000 LPH |
Operating Pressure | 6 MPa |
Line Size | 15MM - 50 MM |
Power Supply | 230 VAC |
Accuracy | +- 1% FSD |
Country of Origin | Made in India |
Rotor | S.S-410 |
Shaft | Hard Stainless Steel-316 With Carbon Bush |
Accuracy Standard Installation Position | +/- 0.5 or 1% FSD |
Repeatability | 0.1% |
Maximum Working Pressure | 6 MPa |
Fluid and Ambient Temperature | -20 to 120 Deg. C |
Connection | Thread (M/f) |
Power Voltage | 12 V DC |
Output Signal | NPN open connector |
High Electric Level | High than 8VDC(input voltage 12 VDC) |
Low Electric Level | Lower Than 0.8 Vdc( Input Voltage 12 Vdc) |
Display Type | ATN - P200R |
Function | Flow Rate Switch |
Mounting | Pannel |
Size | 96x96 |
Input | Pulse |
Output | 2 a pot. Free relay @ 230vac |
Supply | 230 Vac |
PANNEL SS TURBINE FLOW RATE SWITCH- ATN-TRS400-P200R-40NB
ATN Instruments developed and design turbine flow meter available with varient of output : RS 484/ hart/ pulse/ current 4 -20 ma and voltage linear 0-10 vdc, conventional turbine flow sensor and meter for low viscous liquid and gas application, turbine flow sensor model number defined in two category,
1) Heavy duty turbine flow sensor and meter: it's a fully stainless steel meter with carbide bearing and available from 4mm to 400 mm line size
Minimum Order Quantity | 1 Piece |
Usage/Application | Automotive |
Model Name/Number | ATN-TRS400-P300-20NB |
Brand | ATN INSTRUMENTS |
Output | 4 - 20 Ma |
Application Media | Water |
Display | Local, Led |
Operating Temperature | -20 to 120 Deg. C |
Flow Range | 40 - 20000 LPH |
Automation Grade | Automatic |
Condition | New |
Operating Pressure | 6 MPa |
Line Size | 15MM - 50 MM |
Meter Type | Electronics |
Power Supply | 230 VAC |
Size | 96x96 |
Country of Origin | Made in India |
Shaft | Hard Stainless Steel-316 With Carbon Bush |
Accuracy Standard Installation Position | +/- 0.5 or 1% FSD |
Repeatability | 0.1% |
Maximum Working Pressure | 6 MPa |
Fluid and Ambient Temperature | -20 to 120 Deg. C |
Connection | Thread (M/F) |
Power Voltage | 12 V DC |
Output Signal | NPN Open Connector |
Low Electric Level | Lower Than 0.8 Vdc( Input Voltage 12 Vdc) |
Display Type | ATN-P300 |
Function | Flow Transmitter |
Mounting | Pannel |
Input | Pulse |
Supply | 230 Vac |
PANNEL SS TURBINE FLOW TRANSMITTER- ATN-TRS400-P300-20NB
ATN Instruments developed and design turbine flow meter available with varient of output : RS 484/ hart/ pulse/ current 4 -20 ma and voltage linear 0-10 vdc, conventional turbine flow sensor and meter for low viscous liquid and gas application, turbine flow sensor model number defined in two category,
1) Heavy duty turbine flow sensor and meter: it's a fully stainless steel meter with carbide bearing and available from 4mm to 400 mm line size
Usage/Application | Automotive |
Model Name/Number | ATN-TRP400-300B-25NB |
Brand | ATN INSTRUMENTS |
Output | Nill |
Application Media | Water |
Display | Local |
Operating Temperature | 25 - 65 deg.c |
Flow Range | 40-30000 LPH |
Operating Pressure | 5 BAR |
Line Size | 15MM - 50 MM |
Power Supply | Battery Operated |
Accuracy | +- 1% FSD |
Country of Origin | Made in India |
Turbine flow Meter - ATN-TRP400-300B-25NB
Turbine flow meter are prefered for clean, filtered, low viscousity, fluid.
Turbine Flow Meter use the machanical energy for fuild to rotate a pinwheel(rotor) in the flow stream.
Usage/Application | Automotive |
Model Name/Number | ATN-TRP400-L2.1 |
Brand | ATN INSTRUMENTS |
Output | Pulse |
Material | Plastic |
Application Media | Water |
Operating Temperature | Upto 80 deg |
Flow Range | 500 - 5000 lph |
Operating Pressure | Upto 10 bar |
Application Media | Water |
Brand | ATN INSTRUMENTS |
Operating Temperature | (-20 to 120) Deg. C |
Accuracy | +- 1% FSD |
Display Type | LCD / LED |
Usage/Application | Automotive |
Material | Stainless Steel |
Output | 2 RELAY OUT |
Display | Remote, Led |
Flow Range | 3.5 - 21000 LPM |
Operating Pressure | 12 BAR |
Line Size | 15 MM - 300 MM |
Model Name/Number | ATN-TRS400-P200B-25NB |
Shaft | Hard Stainless Steel-316 With Carbon Bush |
Accuracy Standard Installation Position | +/- 0.5 Or 1% Fsd |
Repeatability | 0.1% |
Maximum Working Pressure | 6 Mpa |
Fluid and Ambient Temperature | -20 To 120 Deg. C |
Connection | Thread (M/f) |
Power Voltage | 12 V DC |
Output Signal | Npn Open Connector |
High Electric Level | High Than 8vdc(Input Voltage 12 Vdc) |
Low Electric Level | Lower Than 0.8 Vdc( Input Voltage 12 Vdc) |
Display Sensor | ATN-P200B |
Function | Flow Batcher |
Mounting | Pannel |
Size | 96x96 |
Input | Pulse |
Supply | 230 Vac |
PANNEL SS TURBINE FLOW BATCHER- ATN-TRS400-P200B-25NB )
Turbine flow meter
ATN Instruments developed and design turbine flow meter available with varient of output : RS 484/ hart/ pulse/ current 4 -20 ma and voltage linear 0-10 vdc, conventional turbine flow sensor and meter for low viscous liquid and gas application, turbine flow sensor model number defined in two category,
1) Heavy duty turbine flow sensor and meter: it's a fully stainless steel meter with carbide bearing and available from 4mm to 400 mm line size
Usage/Application | Automotive |
Model Name/Number | ATN-TRS400-F200R-15NB |
Brand | ATN INSTRUMENTS |
Application Media | Water |
Display | Local, Led |
Enclosure | SS-316 |
Rotor | SS-410 |
Shaft | Hard Stainless Steel-316 With Carbon Bush |
Accuracy Standard Installation Position | +/- 0.5 Or 1% Fsd |
Repeatability | 0.1% |
Maximum Working Pressure | 6 Mpa |
Fluid and Ambient Temperature | -20 To 120 Deg. C |
Connection | Flange |
Power Voltage | Battery |
Output Signal | Npn Open Connector |
High Electric Level | High Than 8vdc(Input Voltage 12 Vdc) |
Low Electric Level | Lower Than 0.8 Vdc( Input Voltage 12 Vdc) |
Display Sensor | ATN-F200R |
Function | Flow Rate Switch |
Mounting | Field |
Size | Round Display |
Input | Pulse |
Output | 2a Pot . Free Relay @ 230vac |
FIELD SS TURBINE FLOW RATE SWITCH- ATN-TRS400-F200R-15NB
Turbine flow meter
ATN Instruments developed and design turbine flow meter available with varient of output : RS 484/ hart/ pulse/ current 4 -20 ma and voltage linear 0-10 vdc, conventional turbine flow sensor and meter for low viscous liquid and gas application, turbine flow sensor model number defined in two category,
1) Heavy duty turbine flow sensor and meter: it's a fully stainless steel meter with carbide bearing and available from 4mm to 400 mm line size
Usage/Application | Automotive |
Model Name/Number | ATN-TRP400-P200-15NB |
Brand | ATN INSTRUMENTS |
Output | Nill |
Application Media | Water |
Display | Remote |
Operating Temperature | 25 - 65 deg.c |
Flow Range | 40-30000 LPH |
Operating Pressure | 5 BAR |
Line Size | 15MM - 50 MM |
Power Supply | 230 VAC |
Accuracy | +- 1% FSD |
Country of Origin | Made in India |